add information about smartctl and 3ware raid controller

This commit is contained in:
Blast0r 2020-01-16 16:58:23 +01:00
parent b484fab6ef
commit 1acadafde8
1 changed files with 70 additions and 0 deletions

70
smart-data/README.md Normal file
View File

@ -0,0 +1,70 @@
# Smart-Data
Man kann doch mit den 3Ware-9650SE Raid-Controllern die Smart werte auslesen.
z.b.:
```bash
smartctl -a -d 3ware,<vportID> /dev/twa0
```
Die <vportID> (hier 0-15) kann man über die tw_cli nachschauen, hier mit beispielausgabe:
```bash
# get controller identifier (may change after reboot)
$ sudo tw_cli show
Ctl Model (V)Ports Drives Units NotOpt RRate VRate BBU
------------------------------------------------------------------------
c6 9650SE-16ML 16 16 16 0 4 1 OK
Encls Slots Drives Fans TSUnits PSUnits
-----------------------------------------------------
e0 16 16 8 4 0
# c6 is the controller ID
# lets show all of this controller
$ sudo tw_cli /c6 show
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 JBOD OK - - - 1863.02 Ri OFF
u1 JBOD OK - - - 1863.02 Ri OFF
u2 JBOD OK - - - 1863.02 Ri OFF
u3 JBOD OK - - - 1863.02 Ri OFF
u4 JBOD OK - - - 1863.02 Ri OFF
u5 JBOD OK - - - 1863.02 Ri OFF
u6 JBOD OK - - - 1863.02 Ri OFF
u7 JBOD OK - - - 1863.02 Ri OFF
u8 JBOD OK - - - 1863.02 Ri OFF
u9 JBOD OK - - - 1863.02 Ri OFF
u10 JBOD OK - - - 1863.02 Ri OFF
u11 JBOD OK - - - 1863.02 Ri OFF
u12 JBOD OK - - - 1863.02 Ri OFF
u13 JBOD OK - - - 1863.02 Ri OFF
u14 JBOD OK - - - 1863.02 Ri OFF
u15 JBOD OK - - - 1863.02 Ri OFF
VPort Status Unit Size Type Phy Encl-Slot Model
------------------------------------------------------------------------------
p0 OK u0 1.82 TB SATA 0 - WDC WD2002FYPS-01U1
p1 OK u1 1.82 TB SATA 1 - WDC WD2003FYYS-02W0
p2 OK u2 1.82 TB SATA 2 - WDC WD2002FYPS-01U1
p3 OK u3 1.82 TB SATA 3 - WDC WD2002FYPS-01U1
p4 OK u4 1.82 TB SATA 4 - WDC WD2002FYPS-01U1
p5 OK u5 1.82 TB SATA 5 - WDC WD2002FYPS-01U1
p6 OK u6 1.82 TB SATA 6 - WDC WD2002FYPS-01U1
p7 OK u7 1.82 TB SATA 7 - WDC WD2002FYPS-01U1
p8 OK u8 1.82 TB SATA 8 - WDC WD2002FYPS-01U1
p9 OK u9 1.82 TB SATA 9 - WDC WD2002FYPS-01U1
p10 OK u10 1.82 TB SATA 10 - WDC WD2002FYPS-01U1
p11 OK u11 1.82 TB SATA 11 - WDC WD2002FYPS-01U1
p12 OK u12 1.82 TB SATA 12 - WDC WD2002FYPS-01U1
p13 OK u13 1.82 TB SATA 13 - WDC WD2002FYPS-01U1
p14 OK u14 1.82 TB SATA 14 - WDC WD2002FYPS-01U1
p15 OK u15 1.82 TB SATA 15 - WDC WD2000FYYZ-01UL
Name OnlineState BBUReady Status Volt Temp Hours LastCapTest
---------------------------------------------------------------------------
bbu On Yes OK OK OK 0 xx-xxx-xxxx
```
die erste Tabelle zeigt alle konfigurierten "Units" an, hier sind alle platten als jbod konfiguriert. \\
In der Zweiten Tabelle ist steht vorne die Vport, davon ist nur die Zahl als <vportID> zu verwenden.\\