uc: Quadruple the sampling rate to 488.28Hz, define distinct default sensor IDs, configure meterconstant through a TYPE setting.

This commit is contained in:
Bart Van Der Meerssche 2009-10-28 14:26:47 +00:00
parent f7697b700e
commit 36ceaf4790
2 changed files with 18 additions and 8 deletions

View File

@ -207,8 +207,8 @@ void setup()
ACSR |= (1<<ACBG) | (1<<ACIE) | (1<<ACIS1) | (1<<ACIS0); ACSR |= (1<<ACBG) | (1<<ACIE) | (1<<ACIS1) | (1<<ACIS0);
// Timer2 normal operation // Timer2 normal operation
// Timer2 clock prescaler set to 32 => fTOV2 = 1000kHz / 256 / 32 = 122.07Hz // Timer2 clock prescaler set to 8 => fTOV2 = 1000kHz / 256 / 8 = 488.28Hz (DS p.158)
TCCR2B |= (1<<CS21) | (1<<CS20); TCCR2B |= (1<<CS21);
TIMSK2 |= (1<<TOIE2); TIMSK2 |= (1<<TOIE2);
// disable digital input cicuitry on ADCx pins to reduce leakage current // disable digital input cicuitry on ADCx pins to reduce leakage current
@ -217,7 +217,7 @@ void setup()
// select VBG as reference for ADC // select VBG as reference for ADC
ADMUX |= (1<<REFS1) | (1<<REFS0); ADMUX |= (1<<REFS1) | (1<<REFS0);
// ADC0 selected by default // ADC0 selected by default
// ADC prescaler set to 16 => 1000kHz / 8 = 125kHz // ADC prescaler set to 8 => 1000kHz / 8 = 125kHz (DS p.258)
ADCSRA |= (1<<ADPS1) | (1<<ADPS0); ADCSRA |= (1<<ADPS1) | (1<<ADPS0);
// enable ADC and start a first ADC conversion // enable ADC and start a first ADC conversion

View File

@ -19,12 +19,22 @@
// $Id$ // $Id$
// //
#define SENSOR0 "0123456789abcdef0123456789abcdef" #define SENSOR0 "0123456789abcdef0123456789abcde0"
#define SENSOR1 "0123456789abcdef0123456789abcdef" #define SENSOR1 "0123456789abcdef0123456789abcde1"
#define SENSOR2 "0123456789abcdef0123456789abcdef" #define SENSOR2 "0123456789abcdef0123456789abcde2"
#define SENSOR3 "0123456789abcdef0123456789abcdef" #define SENSOR3 "0123456789abcdef0123456789abcde3"
#define METERCONST 45205 // 29165 * 1.55 #define TYPE 2301
#if TYPE = 2301 // 230V - 1-phase @ 488.28Hz sampling rate
#define METERCONST 7091
#elif TYPE = 2303 // 230V - 3-phase @ 488.28Hz sampling rate
#define METERCONST 7026
#elif TYPE = 2401 // 240V - 1-phase @ 488.28Hz sampling rate
#define METERCONST 7399
#elif TYPE = 2403 // 240V - 3-phase @ 488.28Hz sampling rate
#define METERCONST 7331
#endif
#define START 0 #define START 0
#define END3 0xffffffff #define END3 0xffffffff